AAV Standards Empty Capsids

AAV Reference Standards (Empty Capsids)

AAV is known to produce empty particles without payloads.   AAV reference standards (empty capsids) are well characterized AAV empty viral particles. High quality and high purity AAV reference standards (empty capsids) can be used as controls and standard materials in assays, including HPLC, ELISA, etc. We offer these AAV reference standards in AAV1, AAV2, AAV5, AAV6, AAV8 and AAV9 serotypes.

Custom Reference Standards (Request A Quote) >

See the complete list of All AAV Reference Standards (empty capsids) >

Explore the Fully-characterized AAV Reference Standards (Empty Capsids)

Serotype specific AAV empty particles are produced via transient transfection, purified using ultracentrifugation, followed with chromatographic purification. The empty viral particles are analyzed with both molecular-based assays and transmission electron microscopy (TEM) for full viral vector characterizations, including full-to-empty ratio.

The AAV standard materials (empty capsids) are characterized for purity, viral particles per mL, as well as full/empty ratio. A few thousands of vials per lot are available for each serotype of AAV reference standard.

TEM Analysis of AAV Reference Standards (Empty Capsids)

Fig.1. TEM (transmission electron microscope) image of purified AAV9 empty particles. Empty capsids appear as spheres with black dots in the center (black arrow).

Purity of AAV Reference Standards (Empty Capsids) Analyzed With Silver Staining

Fig. 2. Silver staining of AAV reference standards (empty capsids).
AAV reference standard materials were loaded on a Bis-Tris SDS-PAGE gel. Proteins were detected with silver staining.

Stability of AAV Reference Standards

The stability of AAV reference standards was demonstrated with a separate stability study of rAAV at 3E+12 GC/mL. The AAV vectors were stored at -80oC for 2 years. Viral genome titer and total particle titer did not change by qPCR and ELISA assays. The stability of the reference standard (empty capsids) will be conducted in an ongoing manner. ELISA test will be performed following storage at -80oC, at 3 months, 6 months, and yearly afterwards.

What Can AAV Reference Standards (Empty Capsids) be used for?

Well characterized AAV empty standard materials can be used for characterization of rAAV stocks and as AAV controls.

  • Standard materials for ELISA, HPLC assays
  • Reference materials for in-house standard materials
  • Control viral vectors
AAV sidepanel

Need Custom AAV Standard Materials?

If you need a larger scale or a different serotype of AAV reference standards, we can provide custom production for you. The same production procedure and analytical methods will be used as the catalog AAV reference standard materials. Please contact us.

5 Items

per page
Set Descending Direction
  1. AAV1 Reference Standards (Empty Capsids)
    RS-AAV1-ET
    AAV Empty Capsids
    AAV1
  2. AAV2 Reference Standards (Empty Capsids)
    RS-AAV2-ET
    AAV Empty Capsids
    AAV2
  3. AAV5 Reference Standards (Empty Capsids)
    RS-AAV5-ET
    AAV Empty Capsids
    AAV5
  4. AAV6 Reference Standards (Empty Capsids)
    RS-AAV6-ET
    AAV Empty Capsids
    AAV6
  5. AAV9 Reference Standards (Empty Capsids)
    RS-AAV9-ET
    AAV Empty Capsids
    AAV9

5 Items

per page
Set Descending Direction

AAV is known to produce empty particles without payloads.   AAV reference standards (empty capsids) are well characterized AAV empty viral particles. High quality and high purity AAV reference standards (empty capsids) can be used as controls and standard materials in assays, including HPLC, ELISA, etc. We offer these AAV reference standards in AAV1, AAV2, AAV5, AAV6, AAV8 and AAV9 serotypes.